Thinking its the compressor or really dont know at this point. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. If your previous pump was also 230V, as it likely was Im not sure what could be the problem, probably not a bad pump, but maybe some wire is disconnected, from the terminal board to the capacitor, for example, or otherwise mis-wired, internally perhaps? When impellers are clogged sometimes they surge. Pump is less than 3 years old. After cleaning the pool the pool pump would just hum and not start. The capacitor is at 9 oclock and the thermal regulator at 12 oclock. Hmmm, not too sure about this question Jay, there must be some explanation. Do you feel my capacitor is going bad or my motor? How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. Any ideas? It does this everyday and then starts working like normaly for the rest of the day. Im having a problem with my super pump. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. Is this a ground issue or something else? The electrician checked wiring and installed new breaker and does same thing. Just bought a hayward super II pump. I turned it off overnight but still the same thing. Took it to pool mart and they cleaned it out and said everything was fine inside it. I have a blue essense 20,000 salt system and can find very little online. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. Check that the pump lid is on very tight, and that the threaded fitting that screws into the front of the pump has Teflon tape or other thread sealant. Hi Davy,I have a Hayward pump and its not priming.The basket is only filling up halfway with water. In most cases, it means that your motor is on the way out. "
i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. Please note the breaker is not tripped. If I leave it plugged in then it stays hot, but if I unplug it then it cools off and itll work till it overheats again. Currently it is at pool level. I also have voltage (115 volts)on both sides of the fuse holder with no fuse installed. It's a little over 3 years old and the cell checked out fine. There may also be air leaks on your pump, particularly the pipe or valve that is threaded into the pump, must be sealed with thread sealant tightly. Found this blog, followed the instructions by removing the capacitor and thermal overload, turnied the shaft with a 7/16s. What am I not doing? Any ideas how to address this? Sometimes I am able to get it going by switching the breaker on/off several times, but most times I can hear the motor trying to start for a couple of seconds before it trips the breaker again and again. Once we turn the pump on it runs good for a couple of mins then then once it builds up pressure the water pressure into the pool slowly stops. Second possibility is the pump is too high above water level. When I (electrician) arrived I was able to measure 38volts to ground in the water when the main pump (Hayward Tristar) is running. Grids not aligned properly, thus not pushed fully up into manifold Anyone else have a scientific explanation? There should be NO elbow after the flow switch. Hi, could be that the capacitor has worn out. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Does it sound like the capacitor or could something else be the culprit? As to the filter, pool filters need to be matched to the flow rate of the pump. Hi the strainer housing must need to be tightened up. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. with UV, Ozone and Hydroxyl Radicals. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Hi Dave..your honest opinion please..new 14000gal gunite pool with hayward sp3400vsp pump September 2014,ran a month winterized and ran fine for 3 years, when company came to open up the pool in 2017,pump stuck,installed new 3400@ $1200. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. The problem lies where the power dies [note to readers: motor cycling is not the same as pump cycling, where the water flow starts and stops, here I am talking about the motor itself starting/stopping], I have a Hayward sp2607x10 pump. The pump is connected after the filter and before the salt chlorinator. For AquaRite, move the switch from auto to off and check all of the readings. I rechecked the wiring, everything seems good. Pressing on/off buttom followed only by click sound of switch. I also made sure that the board was changed from T9 to T3 cell. Use a Drain King to pressurize the pipe backwards, to remove such clogs. have an old hayward flo lx pump and sounds like it is turning on with a click but wont start sucking the water from the pool through the pump to the filter. The cell amperage is above the maximum limit. Find answers to your questions about all Just disconnect wires, and replace. from Guess I was wrong. 9-17-2020 If so, you need stronger hose (or pipe), or add another suction pipe (and wall fitting). Is there a trick to this? An error was detected in the ignition control circuit board. What should i do now? 1. What is the problem. Is that a result of all the water that got in the equipment during the storm? Enzyme treatment to the pool can remove oils (if the sand seems oily), and Stain & Scale chemicals can tie up minerals like calcium (if the sand seems crusty). Click OK to extend your time for an additional 0 minutes. Hi Jim, check the wire connections, and the voltage coming into the motor. Can it be repaired or do we need a new pump? This happens even when the filter and skimmer basket is clean. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Troubleshooting Guides To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Hi, loud screeching sounds like bearings, yes. If there is input power, the fuse may have blown. Could the filter be plumbed backwards possibly? I dont see any leaks n pressure seems little bit higher than normal. All check ok. Of course, be sure the pool water level is good, and the skimmer weir door is not stuck, or blocking water flow into a skimmer. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. It looks old and Im thinking about replacing it. Possibly an obstruction on the return line, after the filter? But most plastic impellers are closed nowadays, with non-visible vanes. After filter was fully re-assembled- pump would turn on. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. Thank you. A very thin layer of rust develops between the stator and the rotor inside the motor, and getting a 7/16 open end wrench on the end of the shaft, and working it back and forth, breaks the rust and frees up the shaft to spin. FYI I moved the voltage selector to 115. dual-speed pool pump. Breakers do wear out, especially if used often as the pump switch. I keep reading that it could be a seal. I just want to clarify..we had a problem with the fuse box and its just been changed. If the pump is too large and powerful for the system and pipe size (and Northstars are BIG pumps), the cavitation can cause the motor to overwork. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? Checked breakers etc tried again and it came onbut very loud. ), or the valves that are before the pump. I just purchased a pool home that is utilizing a Hayward Northstar SP4020NS I have noticed that when the pump shuts off water briefly blows out of the strainer cover, like a pressure release. I have no display showing. Today it completely shutdown at some point and tripped the breaker in the house. When it shuts off, you could also test power, to be sure power is still reaching the motor, with a multimeter tester. If it makes no noise at all, that is often a loose wire or no power. Hi if a 2-speed motor only works on low speed, that is usually a loose wire or hi/lo switch. Hope that helps! Not the power leads, but other connecting wires from the terminal board to the switch, to the cap? It leaks where the seal plate connects to the pump/strainer housing. Ray1davis@comcast .net. I checked the power to the timer and I have 120 v to L1 & L2 but timer not running & pump wont run when I turn pump on manually. . Does anyone know how to reset an sf error code after a new thermistor has been installed? The AquaTrol Are T-Cells interchangeable on Hayward AquaRite Systems? Good luck ~, I have a salt water inground pool the other day i noticed my pressure is going up and down from 14psi to like 4 to 6 then back up even couple of mins. Hi Chuong, the Leslies RS750CA is the same as the Hayward Super II pump, which are $500-$600. If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. Follow disassembly/assembly procedures (pages 32 -37). Tim, all I can think of is maybe the pump is not self-priming pump? If your new pump is the exact same make/model/horsepower as the old pump, then the pump is not the problem but if you switched make/models check the pump flow curve, because even though it may be the same hp, different make/model pool pumps produce Vastly different flow rates. Any new postings here are unlikely to be seen or responded to by other members. If power is tested at these points, I would check the motor terminals. Are I on the right track? If the filter multiport was recently re plumbed, be sure that the pipe from the pump goes into the valve port labeled PUMP, and the pipe to the pool is connected to the valve port labeled RETURN. Is my pool pump dead? Check that they are tight and havent come loose. Thanks for the schema!! So changed out the motor with a Century model. Any thoughts? "caption": "In The Swim Blog"
I presume Ill be looking at buying a new pump next year. Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. Attach a bond wire to the Eco star drive pump or tighten the loose screws on the bottom of the motor. Incorrect sizing can cause multiple problems, including low water flow. Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. If so, you can replace just the motor, or the entire pump. $5.99 $3.99 As low as $1.79 WFO RS-23-SED Sediment Water Prefilter Compatible With Culligan S7011C & 00-4015-38 AquaCleer Good Water Machine $16.99 $9.99 As low as $7.99 The outlet the pump is plugged into, I suppose that is a 240V outlet. Are you getting 230V (207v 253V) at the pump? Is there a thicker housing oring that could be installed to fix the leak? My pump seems to trip the GFCI breaker each time it is plugged in. Do you have any suggestion for similar pump? Hi, yes shaft seal failure. 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Hi Shaun, if its not an air leak (from a loose pipe going into the pump, or loose pump lid, or low water level, or stuck skimmer weir), it then most likely is a clogged pump impeller. BUT THE BEARINGS. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. By following the steps listed below, the Aqua Rite can successfully be restored.To view this guide step by step on our website, visit:http://www.inyopools.com/HowToPage/how_to_troubleshoot_a_hayward_aqua_rite.aspx I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. "address": "",
Work through the list below if your Hayward pool heater is on the fritz. "logo": {
If the capacitor doesnt fix it, you may need a new motor, or pump, barring other issues that can be seen readily. We would like to show you a description here but the site wont allow us. Either the pump lid oring is missing, or the lid (cover) is not tight, or a loose threaded pipe coming into the pump, or leaky valves (skimmer, main drain) air leaks are always in front of the pump. Thanks Davy. My pump motor runs for 3-5 minutes ant then shuts off for about the same time. Ive tried everything. hi quick question, i have replaced the bearing for the pump but when i reassembled the pump ive noticed that if i shut the pump off and want to turn it right back on most of the time it hums like the start capactor is not working but if i shake the pump it will start up. If not, but the shaft and impeller spin freely remove the start capacitor, normally located in the motor rear, at 9 oclock, and write down the MFD number, and then order one online, or at a local electric motor repair shop. Hi Davy! Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. We replaced all the seals in the pump and ran a completely new line even from the pump directly into the pool and it will not hold prime. I was able to isolate all the other electrical circuits at the Aqua Logic power panel. My Hayward Pump Super shuts off and then starts then shuts off and then starts again. The salt level is 2300 ppm or less and no chlorine is generating. You can plug the pump into a long extension cord and test it with another outlet on the house, to rule out problems with the outlet its plugged into now. Have had it for 4-5 years and have had no issues. Please remove additional products. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. Could be a loose lid, or the basket not re-placed properly, and a clogged pump impeller. More commonly, you may experience sparks, or a small popping sound as you drain the capacitor, if there is a lot of power stored. Could that be the voltage then or is there another possibility? But most aboveground pool pumps are 115V, and certainly is if it came with the cord. Could also be a loose high speed wire from the switch. If it an older installation, I would again check the water chemistry to make sure it is balanced correctly. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. I have a Hayward super pump 1HP. Pump lid not on tight enough Troubleshooting Guides; Troubleshooting Guides. Hi BRian, nothing special no make sure the outlet TEST button is not popped or tripped? Also, make sure you plug in the cell all the way. Blue essence salt chlorine generator owner's manual I made sure the basket was seated properly and put grease on the o-ring on the cover and made sure it was tight. View Details Usfitnessfinder.com. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. Could be a problem with the centrifugal switch, located dead center on the rear of the motor, or the stationary switch, located beneath it, and contacting each other in the center. I just dont know when it was purchased or how to even find out from the previous owners. MY PUMP STARTS TO PRIME THEN LOSES IT. Hi Tammy, could be many things. Do I need to do something else to get it to prime faster? One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. I also suspect a bad pressure gauge, if flow is nearly non-existant, pressure should be very low. Anyway, have you checked the cleaner line strainer? I have a Hayward pump and filter system for my outdoor water feature. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. Its never happened before. You can experiment with pump RPM settings, to exceed the threshold. Inspect the following areas: If you see air bubbles coming from the return fittings on the pump, there may be an air leak on the suction side. Could also be loose connections on the wires, or insect infestation on the contacts. "author": {
The o-ring should be a very tight fit also, not loose in the groove of the lid. could be cord problem, too. A new o-ring may be needed. I believe we have the drawing in air issue at filter, I cannot locate to purchase the o ring seal and valve cover for this model. Did you figure out your problem? Any ideas? Mine is doing same thing. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, youre sure to find a solution quickly! I checked impeller and seems to be spInning freely with no debris. thanks. Troubleshooting and diagnosing their problems. So I inspected the wiring into the electrical panel. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. It appears to be stuck. I If needed, get yourself ECX1014A, bump shaft kit, for a little rebuild. For Pools up to 40,000 gallons. Was running fine. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. search, pool & drain cover safety If no, test power on the wires coming into the pump, place test meter leads on the red and black wires, with power turned on to the pump. To rule out the filter, if you have a multiport valve, run the pump on the Waste or Recirculate position. If you see any damage, replace your flow switch. I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. If thats what is happening, then the cause of the overheating could be incorrect voltage or fluctuating voltage, incorrect wire size (from breaker or timer to motor), faulty wiring between some of the switches in the rear of the motor, or bad shaft bearings, or poor airflow or blocked air vents, or in some cases, very poor water flow. Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. Tried to backwash. K-1766 Taylor Salt Test My first thought is that the breaker may be too small for the amount of amps needed to start each piece of equipment. I have been getting GFI breaker trips intermittently.